Utilization of a Pressure Cooker for Homemade High-Temperature Sterilization of Rendang
- 1 Department of Food and Agricultural Product Technology, Universitas Andalas, Limau Manis Campus, Padang, Indonesia
- 2 Department of Food and Agricultural Product Technology, Universitas Andalas, Limau Manis Campus, Padang, India
- 3 Department of Agro-Industrial Technology, Universitas Andalas, Limau Manis Campus, Padang, Indonesia
- 4 Department of Industrial Engineering, Universitas Andalas, Limau Manis Campus, Padang, Indonesia
- 5 Department of Management, Universitas Andalas, Limau Manis Campus, Padang, India
- 6 Mitra Karya Analitika Company, Semarang, Indonesia
Abstract
This study aimed to analyze the impact of pressure cooker (presto) sterilization on the nutritional value and microbial content of rendang, a traditional Indonesian meat dish. The evaluated parameters included moisture content, ash content, fat content, protein content, and total plate count (TPC), measured before and after a 40-minute sterilization process. The results showed a moderate increase in moisture (from 32.66-37.67%) and fat content (from 29.86-32.01%), with slight decreases in ash (from 3.47-3.30%) and protein content (from 35.01-33.05%). The TPC was significantly reduced from 1.1×10⁸-6.7×10⁴ CFU/g, indicating a 4-logreduction, which demonstrated the potential of pressure-cooking to lower microbial loads. Although the calculated F₀ value was only 0.17 that indicated well below the recommended threshold of 3 for commercial sterilization, no substantial degradation of nutritional quality was observed. Preliminary results indicated a possible presence of Clostridium botulinum in the sterilized samples; however, this finding required further verification through more specific microbial testing. These findings highlighted the practicality of pressure cooker sterilization as a low-cost and accessible method for small-scale or home-based food industries to improve product safety and extend shelf life. Nonetheless, further optimization, particularly in increasing sterilization duration and ensuring proper thermal processing, is necessary. Additional validation studies were recommended to confirm pathogen inactivation and to establish reliable safety standards for wider application.
DOI: https://doi.org/10.3844/ojbsci.2025.563.569
Copyright: © 2025 Daimon Syukri, Rini, Risa Meutia Fiana, Jonrinaldi, Ratni Primalita, Quratul Aisyah, Hiyang Hidayati Sukma, Yasmin Azzahra, Aurelia Amaliyah Tarumiyo and Deden Dermawan. This is an open access article distributed under the terms of the
Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
- 78 Views
- 52 Downloads
- 0 Citations
Download
Keywords
- F0 Value
- Pressure Cooker
- Rendang
- Sterilization